Steel Fire Rated Door with Panic Bar
Reliable Steel Fire Rated Doors with Panic Bar for Commercial Emergency Exits – Custom Sizes, Hardware Options & Factory Direct Supply
- Overview
- Recommended Products
Description:
Steel Fire Rated Door with Panic Bar is designed for commercial buildings, industrial facilities, and other projects where fire protection and emergency access are important considerations. Combining a steel door structure with a horizontal panic bar, this door provides a practical solution for designated fire exits and emergency escape routes.
Our steel fire rated door with panic bar is manufactured using galvanized steel sheets, with the door leaf and frame constructed according to project specifications. The internal structure can incorporate fire-resistant materials such as fireproof aggregate and perlite, depending on the selected model and required configuration.
The integrated panic bar allows occupants to open the door by applying pressure to the horizontal push bar from the inside. This provides a convenient exit operation, particularly in areas where people may need to leave quickly during an emergency.
As a professional door manufacturer, we offer customized steel fire rated doors in different sizes, opening directions, finishes, and hardware configurations. Buyers can specify door dimensions, frame profiles, steel thickness, panic bar styles, locks, hinges, and other accessories according to their architectural drawings and project requirements.
Whether you are sourcing a single emergency exit door or multiple units for a commercial construction project, our factory can provide product customization and manufacturing support.
Applications:
Commercial Buildings
In office buildings, shopping centers, and commercial complexes, steel fire rated doors with panic bars can be used at designated emergency exits and escape routes. The push-bar design provides convenient operation for occupants leaving the building.
Industrial Facilities
Factories, warehouses, and manufacturing facilities often require durable metal doors for designated exit locations. A steel fire exit door offers a practical steel construction with customizable dimensions and hardware options.
Hospitals and Healthcare Buildings
Hospitals and healthcare facilities need carefully planned exit routes for staff, visitors, and patients. Panic bar hardware can provide a convenient exit operation where permitted by the building's fire safety design.
Schools and Public Buildings
Schools, educational institutions, and public facilities may use panic bar fire doors at designated exit points. Door dimensions, opening direction, and hardware should be selected according to occupancy requirements and local regulations.
Hotels and Other Commercial Projects
Hotels, apartment buildings, and other commercial properties may incorporate steel fire doors into stairwells, service areas, and emergency exit routes, subject to the approved building design.
Advantages:
1. Durable Steel Door Construction
The steel fire rated door uses galvanized steel sheets for the door leaf and frame. This metal construction provides structural strength and supports regular operation in commercial and industrial environments.
Steel thickness, frame dimensions, and door leaf construction can be adjusted according to project specifications and the selected product model.
2. Convenient Emergency Exit Operation
The panic bar fire door is equipped with a horizontal push bar installed on the inside of the door. Users can operate the door by pushing the bar instead of turning a conventional handle.
This configuration is suitable for designated emergency exits where convenient exit operation is required. The exact panic hardware type and locking configuration can be selected according to project requirements and applicable building regulations.
3. Fire-Resistant Internal Structure
The door leaf can be filled with fire-resistant materials, including fireproof aggregate and perlite, depending on the product design.
The complete fire door assembly, including the door leaf, frame, hardware, and installation details, must meet the applicable fire testing and certification requirements. Available fire ratings should be confirmed for the selected model.
4. Practical Hardware Integration
In addition to the panic bar, the steel emergency exit door can be equipped with hinges, exterior access handles, locks, and door closers according to the required design.
Hardware selection is important because it affects door operation, compatibility, and compliance with project specifications.
FAQ:
1. Q: What is the function of the sealing strips of steel fireproof doors? How often should they be replaced?
A: The sealing strips around the door panel are of expansion type when encountering fire, which normally ensure the sealing and sound insulation of the door. During a fire, they will rapidly expand and fill the gaps to prevent smoke penetration. Under normal usage conditions, it is recommended to check once every 1-2 years. If there is aging, cracking, or shrinking, they should be replaced in time to avoid affecting the fireproof performance.
2. Q: What should be done if there is rust on the surface of the steel fireproof door? How to maintain it daily?
A: If there is slight rust on the surface, it can be ground off with fine sandpaper and then painted with the same color anti-rust paint and spray paint; if the rust is severe, contact the manufacturer to replace the door panel or reapply surface treatment. Daily maintenance should pay attention to: avoid sharp objects scraping the coating, regularly wipe the surface dust with a damp cloth, and add lubricating oil to the moving parts such as hinges and locks every half a year to ensure smooth opening and closing.
3. Q: Can steel fireproof doors be customized in size and color? How long does the customization process take?
A: Yes, customization is possible. The size can be adjusted according to the size of the building opening, and colors support various spray colors such as white, gray, and black, suitable for different decoration styles. The regular size customization process takes about 20-30 days, and special specifications or large-scale customization needs to be appropriately extended according to the production schedule. Specific information can be consulted with the sales staff.
4. Q: When installing steel fireproof doors, what should be used to fill the gap between the door frame and the wall?
A: The gap between the door frame and the wall must be filled with fireproof mortar, fireproof rock wool, etc., and non-fireproof materials such as cement mortar must not be used. Fireproof sealing can ensure that fire does not spread through the gaps during a fire, protecting the overall fireproof effect of the door.
5. Q: What are the differences between steel fireproof doors and stainless steel fireproof doors? How should one choose?
A: The core difference lies in the material and applicable environment: steel fireproof doors use cold-rolled steel plates, which have high cost performance and are suitable for most indoor scenarios; stainless steel fireproof doors use 304 or 316 stainless steel materials, which have strong corrosion resistance, and are suitable for humid, salt spray-containing outdoor or coastal areas. When choosing, consider the humidity, corrosion, and budget of the usage scenario comprehensively.