Steel Fire Door – Custom Steel Fire Rated Doors for Commercial and Industrial Buildings
Custom Steel Fire Doors for Commercial, Industrial and Building Projects
- Overview
- Recommended Products
Description:
A Steel Fire Door is an essential fire protection solution designed to help slow the spread of fire and smoke while providing secure access between different areas of a building. Manufactured with galvanized steel sheets and a fire-resistant core, our steel fire doors are suitable for commercial buildings, industrial facilities, residential projects, hotels, schools, hospitals, and public buildings.
Our Steel Fire Door combines a durable steel structure, practical functionality, and customizable design to meet different project requirements. The door leaf and frame are manufactured using galvanized steel, while the internal core can be filled with fire-resistant materials such as perlite-based materials and other suitable fire-resistant components.
Available in single-leaf and double-leaf configurations, our steel fire doors can be customized according to project dimensions, opening directions, surface finishes, colors, and hardware requirements.
For selected models, we offer 1-hour and 2-hour fire-rated configurations. Specific models are available with WH certification, including certificate No. 250207013SHF-001-R1. Certification applicability depends on the tested door configuration.
As a professional door manufacturer in China, we provide customized steel fire door solutions for distributors, contractors, builders, and international project buyers.
Applications:
Commercial Buildings
Steel fire doors are commonly specified for office buildings, shopping centers, business complexes, and commercial properties. They can be used in corridors, stairwells, service rooms, and other designated fire separation areas.
Industrial Facilities
Factories, warehouses, workshops, and distribution centers may require steel fire doors to separate different functional areas. Their galvanized steel construction makes them suitable for environments where durability and regular operation are important.
Hotels and Residential Buildings
A steel fire door can be used in selected service areas, equipment rooms, electrical rooms, and designated common areas in hotels and residential developments.
Hospitals, Schools and Public Buildings
Public facilities often require carefully specified fire-rated doors as part of their overall fire safety design. Our steel fire door solutions can be customized to meet project dimensions, appearance requirements, and applicable technical specifications.
Before purchasing, buyers should confirm local building codes, required fire ratings, and approved door assemblies with their project consultants.
Advantages:
Durable Galvanized Steel Construction
Our steel fire door features a galvanized steel structure designed for strength, durability, and everyday use. The steel door leaf and frame provide a solid construction suitable for commercial and industrial environments.
The standard configuration can include a 1.0 mm galvanized steel door leaf and a 1.5 mm galvanized steel frame. Steel thickness and structural details can be adjusted according to project specifications and applicable certification requirements.
Fire-Resistant Core Materials
A quality steel fire door requires suitable internal fire-resistant materials. Our door structure can incorporate fire-resistant aggregate and perlite-based core materials to support the required fire performance.
The internal structure, door thickness, hardware, and installation details must match the applicable tested configuration to achieve the specified fire rating.
Multiple Fire Rating Options
We offer steel fire door configurations with different fire resistance requirements, including 60-minute and 120-minute options where supported by the relevant product design and testing.
For projects requiring certified products, buyers can confirm the required certification, testing standard, fire rating, and approved hardware before ordering.
FAQ:
1. Q: What is the function of the sealing strips of steel fireproof doors? How often should they be replaced?
A: The sealing strips around the door panel are of expansion type when encountering fire, which normally ensure the sealing and sound insulation of the door. During a fire, they will rapidly expand and fill the gaps to prevent smoke penetration. Under normal usage conditions, it is recommended to check once every 1-2 years. If there is aging, cracking, or shrinking, they should be replaced in time to avoid affecting the fireproof performance.
2. Q: What should be done if there is rust on the surface of the steel fireproof door? How to maintain it daily?
A: If there is slight rust on the surface, it can be ground off with fine sandpaper and then painted with the same color anti-rust paint and spray paint; if the rust is severe, contact the manufacturer to replace the door panel or reapply surface treatment. Daily maintenance should pay attention to: avoid sharp objects scraping the coating, regularly wipe the surface dust with a damp cloth, and add lubricating oil to the moving parts such as hinges and locks every half a year to ensure smooth opening and closing.
3. Q: Can steel fireproof doors be customized in size and color? How long does the customization process take?
A: Yes, customization is possible. The size can be adjusted according to the size of the building opening, and colors support various spray colors such as white, gray, and black, suitable for different decoration styles. The regular size customization process takes about 20-30 days, and special specifications or large-scale customization needs to be appropriately extended according to the production schedule. Specific information can be consulted with the sales staff.
4. Q: When installing steel fireproof doors, what should be used to fill the gap between the door frame and the wall?
A: The gap between the door frame and the wall must be filled with fireproof mortar, fireproof rock wool, etc., and non-fireproof materials such as cement mortar must not be used. Fireproof sealing can ensure that fire does not spread through the gaps during a fire, protecting the overall fireproof effect of the door.
5. Q: What are the differences between steel fireproof doors and stainless steel fireproof doors? How should one choose?
A: The core difference lies in the material and applicable environment: steel fireproof doors use cold-rolled steel plates, which have high cost performance and are suitable for most indoor scenarios; stainless steel fireproof doors use 304 or 316 stainless steel materials, which have strong corrosion resistance, and are suitable for humid, salt spray-containing outdoor or coastal areas. When choosing, consider the humidity, corrosion, and budget of the usage scenario comprehensively.